Set (Down Limit): The voltage at which the charger starts (Battery Low). When battery voltage >UPis greater than cap U cap P , the output turns off. 4. Parameter Setting (How to Program)
: Here, your battery is the input, and your load (e.g., a DC light) is the output. Set "UP" to the maximum voltage you allow (often left high as a failsafe). Set "dn" to the minimum safe voltage for your battery (e.g., 11.0V for a 12V battery). As long as the battery voltage is above 11.0V, the module will power your light. If the voltage drops to 11.0V, it will disconnect the light, preventing your battery from being drained completely and permanently damaged.
Adds a delay (in seconds) between reaching the activation voltage and the relay actually closing.
After conducting an extensive search, it seems that the "xycd60 manual" might be related to a piece of industrial or technical equipment. The prefix "xyc" could indicate a manufacturer or product code, while "d60" might signify a model number or product variant. Several industrial equipment databases and manufacturer catalogs were reviewed, but no direct matches were found. xycd60 manual
has four terminals: two for input (Battery) and two for output (Load/Charger). Connect to the DC Battery ( +Vpositive cap V −Vnegative cap V
The module features two core programmatic profiles. Selecting the right profile dictates how the physical relay responds to voltage changes. 1. Charging Control Mode ( IN )
Set IN Mode, UP = 14.4V (Stop charging), dn = 12.0V (Start charging). Set (Down Limit): The voltage at which the
A: The module itself acts as a controller and uses an internal relay as a switch. The relay is rated for currents up to 20A. However, you should always check your specific module's relay rating as different manufacturing batches may vary slightly. For very high-current applications, it's advisable to use this device to control a larger external contactor.
| Code | Function | Description | |------|----------|-------------| | P1 | Over-voltage cutoff | Load disconnects if voltage > this value | | P2 | Over-voltage reconnect | Voltage must drop below this to re-engage | | P3 | Under-voltage cutoff | Load disconnects if voltage < this value | | P4 | Under-voltage reconnect | Voltage must rise above this to re-engage | | P5 | Over-current cutoff | Load disconnects if current > this value | | P6 | Delay time (seconds) | Delay before reconnecting after fault | | P7 | Start delay | Delay before relay engages on power-up |
The XY-CD60 is designed for flexibility, supporting a wide range of battery types and voltages. XY-CD60 (or XY-CD60L) Voltage Range: 6V – 60V DC Parameter Setting (How to Program) : Here, your
) and opens (cuts off load) when the voltage falls to the lower limit ( 3. Setting Parameters To configure the module, use the following button sequence: Enter Setting Mode: Long press the Switch Parameters: Short press to cycle through parameters: (upper limit), (lower limit), and (time control). Adjust Values: buttons to increase or decrease values. Save and Exit: Long press for 5 seconds to save and return to the main interface. Switch Modes: Long press the button for 5 seconds to toggle between Charging ( ) and Discharging ( 4. Advanced Functions
The module turns on the load when the voltage is above UP and turns it off when it drops below dn . 4. Operational Features